AUDIO SAMPLES

Output Level - The signal output level was measured for various positions of the Gain In knob, and a completely flat response was observed in the audible spectrum (20Hz - 20kHz) for all measurements.

Phase Distortion - Phase difference was measured at the output for various positions of the Gain In knob, and a maximum phase shift of +-15º was observed at the extremes of the audible spectrum (with 180º being total phase inversion).

Harmonic Distortion and Noise Floor - Harmonic distortion was measured for a medium-gain setting (aiming for a crystal-clear sound), and a maximum distortion of -60dBr was observed in relation to the fundamental tone at low frequencies, decreasing significantly as the frequency increased. The noise floor ranged between -105 and -100 dBr.